{"id":1022,"date":"2026-08-01T23:16:00","date_gmt":"2026-08-01T15:16:00","guid":{"rendered":"https:\/\/www.esair-equip.com\/1022.html"},"modified":"2026-08-01T23:21:09","modified_gmt":"2026-08-01T15:21:09","slug":"vertical-spray-scrubber","status":"publish","type":"post","link":"https:\/\/www.esair-equip.com\/vi\/1022.html","title":{"rendered":"Vertical Spray Scrubber"},"content":{"rendered":"<div class=\"wp-block-cover has-custom-content-position is-position-bottom-center\" style=\"min-height:403px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"358\" class=\"wp-block-cover__image-background wp-image-727 size-large\" alt=\"\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro-1024x358.jpg\" data-object-fit=\"cover\" srcset=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro-1024x358.jpg 1024w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro-300x105.jpg 300w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro-768x269.jpg 768w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro-1536x538.jpg 1536w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/pro.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-black-background-color has-background-dim-30 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:12px;line-height:33px;color:#ffffff;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left has-bonkers-font-size\">S\u1ea3n ph\u1ea9m<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n <div class=\"block_breadcrumbs\"><div class=\"breadcrumbs\"><nav> <a itemprop=\"breadcrumb\" href=\"https:\/\/www.esair-equip.com\/vi\">Home<\/a> \/ <\/nav><\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>\n<\/div><\/div>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined  visible\" id=\"\" style=\"padding-bottom:17px;padding-top:46px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in clomnsmal\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-themepark-block-themepark-product-head content_pro quan\" style=\"background-color:#ffffff;border-radius:6px;margin-bottom:20px;\"><div class=\"tab_pic\"><div class=\"left_post_pic\"><a class=\"swipebox\" href=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356.jpg\"><img decoding=\"async\" class=\"lazy ls-is-cached lazyloaded\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loading8.png\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356.jpg\" alt=\"Vertical Spray Scrubber\" \/><\/div><div class=\"post_gallery_out\"><div class=\"swiper-container post_gallery\" data-v=\"10\" data-b=\"10\"><div class=\"swiper-wrapper\"><div class=\"swiper-slide\"><a class=\"swipebox\" href=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"swiper-lazy swiper-move-lazy\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loading8.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356-150x150.jpg\" width=\"150\" height=\"150\" alt=\"Vertical Spray Scrubber\" \/><\/a><\/div><div class=\"swiper-slide\"><a class=\"swipebox\" href=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266123226383.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"swiper-lazy swiper-move-lazy\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loading8.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266123226383-150x150.jpg\" width=\"150\" height=\"150\" alt=\"Vertical Spray Scrubber\" \/><\/a><\/div><div class=\"swiper-slide\"><a class=\"swipebox\" href=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266131134149.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"swiper-lazy swiper-move-lazy\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loading8.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266131134149-150x150.jpg\" width=\"150\" height=\"150\" alt=\"Vertical Spray Scrubber\" \/><\/a><\/div><div class=\"swiper-slide\"><a class=\"swipebox\" href=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993912648018.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"swiper-lazy swiper-move-lazy\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loading8.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993912648018-150x150.jpg\" width=\"150\" height=\"150\" alt=\"Vertical Spray Scrubber\" \/><\/a><\/div><\/div><\/div><a class=\"swiper-next\"><i class=\"fas fa-angle-right\"><\/i><\/a><a class=\"swiper-prev\"><i class=\"fas fa-angle-left\"><\/i><\/a><\/div><\/div><div class=\"ds\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p MovePnly sticky\" style=\"font-size:16px;line-height:36px;color:#808080;background-color:#ffffff; border:1px #d7d7d7 solid;padding:30px 30px;border-radius:15px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-black-color has-text-color has-link-color has-large-font-size wp-elements-99555ae3e05f4a5d9cb6e2edfc3ca2f8\">Vertical Spray Scrubber<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-c5cc62a0dabaa5abb57a7d937ee66cab wp-block-paragraph\" style=\"font-size:18px\"><strong>Product Classification<\/strong><\/p>\n\n\n\n<a href=\"https:\/\/www.esair-equip.com\/vi\/category\/product\/acid-base-waste-gas-purification-equipment\">Thi\u1ebft b\u1ecb x\u1eed l\u00fd kh\u00ed th\u1ea3i axit-baz\u01a1<\/a> \n\n\n\n<div class=\"wp-block-themepark-block-themepark-xian theme_fang_out\" style=\"text-align:left;padding-top:15px;padding-bottom:15px;\"><div class=\"fangbox\" style=\"width:100%;height:1px;background-color:#e6e6e6;\"><\/div><\/div>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color has-medium-font-size wp-elements-7b3681ca418359f06d4d62aa6a3c41ca wp-block-paragraph\"><strong>Scope of Application<\/strong><\/p>\n\n\n\n<p class=\"has-monte-grey-color has-text-color has-link-color wp-elements-434dba10dab9870bd3f4392b641f9397 wp-block-paragraph\"><\/p>\n\n\n<p>The EXL series vertical spray scrubber is specifically designed for treating most water-soluble pollutants as well as acidic and alkaline exhaust gases.<\/p>\n<p>In addition to removing water-soluble contaminants from industrial exhaust streams, the scrubber can also capture particulate matter larger than the micron level.<\/p>\n<p>Its basic operating principle is to bring the contaminated gas into full contact with the scrubbing liquid, transferring pollutants from the gas phase into the liquid phase. The purified gas is then separated from the contaminated liquid, achieving effective exhaust gas treatment.<\/p>\n\n\n\n\n<p class=\"has-monte-grey-color has-text-color has-link-color wp-elements-434dba10dab9870bd3f4392b641f9397 wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-listbox thempark-block themepark_listbox\" style=\"padding-top:15px;text-align:left;\"><ul class=\"themepark_listbox_list\" style=\"padding-left:0%;padding-right:2%;\"><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-envelope\" style=\"color:#009aab;line-height:28px\"><\/i><span>esairsuzhou@vip.163.com<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>0512-57398857<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>13776305335  \u00d4ng Liu<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>17312699967 Miss luo<\/span><\/li><\/ul><div class=\"themepark_listbox_ba\" style=\"opacity:1;\"><\/div><\/section>\n\n\n\n<div class=\"wp-block-themepark-block-btn themepark-i-btn-out maodian\" style=\"text-align:undefined;padding-bottom:14px;\"><div class=\"themepark-i-btn-out_ins\" style=\"\"><div class=\"themepark-i-btn-out_in\"><div class=\"themepark-i-btn  active\" style=\"background-color:#009aab;color:#ffffff;font-size:16px;border:solid 1px #009aab;border-radius:20px;padding:5px 23px;\"><i class=\"ri-chat-2-fill\"><\/i><a href=\"#Inquiry\" rel=\"noopener noreferrer \">Inquiry<\/a><a class=\"hovers ri-chat-2-fill\" data-title=\"Inquiry\" style=\"color:#009aab;background-color:#ffffff;padding:5px 23px;border-radius:20px;\" href=\"#Inquiry\" rel=\"noopener noreferrer\" target=\"_self\"><\/a><\/div><div class=\"themepark-i-btn\" style=\"background-color:#009aab;color:#ffffff;font-size:16px;border:solid 1px #009aab;border-radius:20px;padding:5px 23px;\"><i class=\"ri-apps-fill\"><\/i><a href=\"#Related\" rel=\"noopener noreferrer\" target=\"_self\">Recommendation<\/a><a class=\"hovers ri-apps-fill\" data-title=\"Recommendation\" style=\"color:#009aab;background-color:#ffffff;padding:5px 23px;border-radius:20px;\" href=\"#Related\" rel=\"noopener noreferrer\" target=\"_self\"><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-9ac00cf961d1ea846fe5a532228b76c6 wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-listbox thempark-block themepark_listbox iconmodle  undefined\" style=\"padding-top:13px;text-align:left;\"><h3 class=\"themepark_listbox_title\" style=\"color:#666666;font-size:18px;\"><span>Share on social media<\/span><\/h3><ul class=\"themepark_listbox_list\" style=\"\"><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-facebook\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>facebook<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/twitter.com\/intent\/tweet?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026text=\"><i class=\"fab fa-twitter\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/twitter.com\/intent\/tweet?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026text=\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>twitter<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.linkedin.com\/shareArticle?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=\"><i class=\"fab fa-linkedin\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.linkedin.com\/shareArticle?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>linkedin<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/api.whatsapp.com\/send?text= https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-whatsapp\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/api.whatsapp.com\/send?text= https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>whatsapp<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.linkedin.com\/shareArticle?mini=trueu0026url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=u0026summary=u0026source=https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-linkedin\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.linkedin.com\/shareArticle?mini=trueu0026url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=u0026summary=u0026source=https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>linkedin<\/span><\/a><\/li><\/ul><div class=\"themepark_listbox_ba\" style=\"opacity:1;\"><\/div><\/section>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-xian theme_fang_out\" style=\"text-align:left;padding-top:15px;padding-bottom:15px;\"><div class=\"fangbox\" style=\"width:100%;height:1px;background-color:#e6e6e6;\"><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:34px;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><h3>Product Overview<\/h3>\n<p>The EXL series vertical spray scrubber is specially designed for treating most water-soluble pollutants as well as acidic and alkaline industrial exhaust gases.<\/p>\n<p>In addition to removing water-soluble gaseous contaminants, the system can also capture micron-sized and larger particulate matter. Its basic treatment principle is to bring the contaminated gas into full contact with a scrubbing liquid, transfer pollutants from the gas phase into the liquid phase, and then separate the purified gas from the contaminated liquid.<\/p>\n<p>Under controlled temperature and pressure conditions, the circulating spray system delivers the washing liquid through high-pressure nozzles. High-efficiency packing material increases the gas-liquid contact area and helps atomize the liquid into fine droplets.<\/p>\n<p>At the beginning of gas-liquid contact, pollutant dissolution and absorption are the dominant processes. As the concentration of absorbed pollutants in the washing liquid increases, the absorption rate gradually decreases while the desorption rate increases.<\/p>\n<p>When the absorption and desorption rates become equal, the system reaches gas-liquid phase equilibrium and the net absorption process stops. At this stage, the saturated washing liquid should be replaced or treated. Otherwise, the absorbed pollutants may escape from the liquid phase and return to the gas phase.<\/p>\n<p>For acid or alkaline exhaust gas treatment, the scrubber can be equipped with an automatic chemical dosing system. Sulfuric acid, alkaline solution or another suitable reagent is introduced into the circulating liquid to react rapidly with the target pollutants and improve neutralization efficiency.<\/p>\n<p><!-- Image 2: Working Principle or Internal Structure Diagram --><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1028 size-full\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5.png\" alt=\"Vertical Spray Scrubber Working Principle\" width=\"1286\" height=\"1223\" srcset=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5.png 1286w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5-300x285.png 300w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5-1024x974.png 1024w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5-768x730.png 768w\" sizes=\"auto, (max-width: 1286px) 100vw, 1286px\" \/><\/p>\n<h3>Working Principle<\/h3>\n<p>The EXL vertical spray scrubber mainly consists of the tower body, spray sections, packing layers, mist elimination section, circulating-water piping, circulation tank and circulating pump.<\/p>\n<p>The spray sections generally use spiral nozzles and high-efficiency packing materials such as Pall rings. Transparent inspection windows can be installed to allow convenient observation of the internal spray and packing conditions.<\/p>\n<p>The mist elimination section can use swirl plates, Raschig rings or other demisting media to remove entrained water droplets from the treated gas.<\/p>\n<p>The circulating pump can be selected from corrosion-resistant plastic pumps or stainless steel centrifugal pumps according to the washing-liquid composition and operating conditions.<\/p>\n<p>Other components, including plastic piping, valves, support frames, inspection ladders and inlet ducts, can be customized according to project requirements.<\/p>\n<p>The vertical spray scrubber is a counter-current gas-liquid absorption tower. Contaminated gas enters tangentially through the lower inlet and rapidly fills the inlet section under the action of the ventilation fan.<\/p>\n<p>The gas then rises evenly through the flow-distribution section. In the spray zone, the absorption liquid is atomized through evenly arranged nozzles, forming fine droplets that fully mix and contact the rising gas.<\/p>\n<p>During this contact process, soluble pollutants transfer into the liquid phase, while acidic or alkaline components react with the corresponding chemical solution.<\/p>\n<p>The treated gas then passes through the mist eliminator to remove entrained droplets. Purified gas exits through the top outlet and is discharged through the exhaust stack after meeting the applicable emission requirements.<\/p>\n<h3>Treatment Process<\/h3>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\n<tbody>\n<tr>\n<td><strong>Process Stage<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>1. Exhaust Gas Collection<\/strong><\/td>\n<td>Contaminated gas is collected through extraction hoods and transported to the scrubber through the duct system.<\/td>\n<\/tr>\n<tr>\n<td><strong>2. Gas Distribution<\/strong><\/td>\n<td>The inlet and distribution section guide the gas evenly into the absorption zone.<\/td>\n<\/tr>\n<tr>\n<td><strong>3. Spray Absorption<\/strong><\/td>\n<td>The circulating liquid is atomized through high-pressure nozzles and fully contacts the rising gas.<\/td>\n<\/tr>\n<tr>\n<td><strong>4. Packing Mass Transfer<\/strong><\/td>\n<td>High-efficiency packing increases the contact area between the gas and liquid phases.<\/td>\n<\/tr>\n<tr>\n<td><strong>5. Chemical Neutralization<\/strong><\/td>\n<td>Acidic or alkaline pollutants react with the automatically dosed washing solution.<\/td>\n<\/tr>\n<tr>\n<td><strong>6. Mist Elimination<\/strong><\/td>\n<td>The mist eliminator removes liquid droplets entrained in the purified gas.<\/td>\n<\/tr>\n<tr>\n<td><strong>7. Purified Gas Discharge<\/strong><\/td>\n<td>The treated gas exits through the upper outlet and is discharged through the exhaust stack.<\/td>\n<\/tr>\n<tr>\n<td><strong>8. Liquid Circulation<\/strong><\/td>\n<td>The washing liquid returns to the circulation tank for reuse until replacement or treatment is required.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Main Components<\/h3>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\n<tbody>\n<tr>\n<td><strong>Component<\/strong><\/td>\n<td><strong>Function<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Vertical Tower Body<\/td>\n<td>Provides the enclosed space required for gas distribution, spraying, absorption and mist removal.<\/td>\n<\/tr>\n<tr>\n<td>Spray Section<\/td>\n<td>Uses nozzles to atomize the washing liquid and maximize gas-liquid contact.<\/td>\n<\/tr>\n<tr>\n<td>Packing Layer<\/td>\n<td>Increases the effective mass-transfer area and improves pollutant absorption efficiency.<\/td>\n<\/tr>\n<tr>\n<td>Mist Eliminator<\/td>\n<td>Removes water droplets entrained in the treated gas.<\/td>\n<\/tr>\n<tr>\n<td>Circulation Tank<\/td>\n<td>Stores the washing liquid for continuous recirculation.<\/td>\n<\/tr>\n<tr>\n<td>Circulating Pump<\/td>\n<td>Delivers the washing liquid from the tank to the spray nozzles.<\/td>\n<\/tr>\n<tr>\n<td>Automatic Dosing System<\/td>\n<td>Adds acid, alkali or other treatment chemicals according to the pollutant characteristics.<\/td>\n<\/tr>\n<tr>\n<td>Inspection Window<\/td>\n<td>Allows observation of the internal spray and packing conditions.<\/td>\n<\/tr>\n<tr>\n<td>Maintenance Door<\/td>\n<td>Provides access for cleaning, inspection and packing replacement.<\/td>\n<\/tr>\n<tr>\n<td>Piping and Valves<\/td>\n<td>Control liquid circulation, drainage, replenishment and chemical dosing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Key Features<\/h3>\n<ul>\n<li>Efficient absorption and neutralization of toxic and harmful gases<\/li>\n<li>Dust collection efficiency can generally exceed 90% under suitable operating conditions<\/li>\n<li>Suitable for water-soluble, acidic and alkaline pollutants<\/li>\n<li>Stable and reliable performance<\/li>\n<li>Simple operation and convenient maintenance<\/li>\n<li>Can be used independently or as a pretreatment unit<\/li>\n<li>Optional packing and automatic chemical dosing systems<\/li>\n<li>Available treatment airflow from approximately 500 to 100,000 m\u00b3\/h<\/li>\n<li>Long equipment service life and relatively low maintenance requirements<\/li>\n<li>Flexible tower materials available according to corrosion and temperature conditions<\/li>\n<li>Customized tower dimensions and process configurations available<\/li>\n<\/ul>\n<h3>Available Construction Materials<\/h3>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\n<tbody>\n<tr>\n<td><strong>Material<\/strong><\/td>\n<td><strong>Typical Application<\/strong><\/td>\n<\/tr>\n<tr>\n<td>PP<\/td>\n<td>Suitable for many acidic, alkaline and corrosive exhaust gas treatment applications.<\/td>\n<\/tr>\n<tr>\n<td>FRP<\/td>\n<td>Provides good corrosion resistance and structural strength for industrial scrubber systems.<\/td>\n<\/tr>\n<tr>\n<td>Q235B Carbon Steel<\/td>\n<td>Suitable for less corrosive conditions with appropriate coating or internal lining.<\/td>\n<\/tr>\n<tr>\n<td>SUS304 Stainless Steel<\/td>\n<td>Suitable for applications requiring improved corrosion resistance, mechanical strength and cleanliness.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Applicable Pollutants<\/h3>\n<ul>\n<li>Acidic exhaust gas<\/li>\n<li>Alkaline exhaust gas<\/li>\n<li>Water-soluble organic and inorganic pollutants<\/li>\n<li>Acid mist<\/li>\n<li>Ammonia and alkaline vapors<\/li>\n<li>Sulfur-containing gases<\/li>\n<li>Industrial odors<\/li>\n<li>Fine dust and particulate matter<\/li>\n<li>High-temperature dusty gas after suitable cooling treatment<\/li>\n<\/ul>\n<h3>Applicable Industries<\/h3>\n<ul>\n<li>Chemical manufacturing<\/li>\n<li>Food processing<\/li>\n<li>Pharmaceutical production<\/li>\n<li>Electronics manufacturing<\/li>\n<li>Steel and metallurgical industries<\/li>\n<li>Non-ferrous metal processing<\/li>\n<li>Mining and mineral processing<\/li>\n<li>Industrial furnace exhaust treatment<\/li>\n<li>Pickling and metal surface treatment<\/li>\n<li>Electroplating production<\/li>\n<li>Battery manufacturing<\/li>\n<li>Laboratory exhaust systems<\/li>\n<li>Other industries generating soluble or corrosive exhaust gases<\/li>\n<\/ul>\n<p><!-- Image 3: Application Site or Installation Image --><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1027 size-full aligncenter\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993719847768.png\" alt=\"Industrial Application of Vertical Spray Scrubber\" width=\"293\" height=\"576\" srcset=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993719847768.png 293w, https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993719847768-153x300.png 153w\" sizes=\"auto, (max-width: 293px) 100vw, 293px\" \/><\/p>\n<h3>Installation Instructions<\/h3>\n<ol>\n<li>Install the vertical spray scrubber on a reinforced concrete foundation at least 150 mm above ground level. Separate concrete foundations should be prepared for the pump and fan where required.<\/li>\n<li>Protect the equipment body, nozzles, packing, piping and other components from impact or damage during transportation and installation.<\/li>\n<li>Depending on the equipment dimensions and transportation conditions, the scrubber may be delivered in sections and assembled on site.<\/li>\n<li>For outdoor installation in cold climates, provide anti-freezing protection for the bottom circulation tank, water piping and pump during winter.<\/li>\n<li>Fill the circulation tank with the required absorption liquid to the marked operating level before startup. Replenish the liquid during operation when necessary.<\/li>\n<li>Reserve adequate space around the scrubber for inspection, cleaning, packing replacement and pump servicing.<\/li>\n<li>Confirm that the fan, pump, valves, dosing system and electrical controls operate correctly before introducing contaminated gas.<\/li>\n<\/ol>\n<h3>Startup Procedure<\/h3>\n<ol>\n<li>Check the liquid level in the circulation tank.<\/li>\n<li>Confirm that the spray nozzles, valves and piping are unobstructed.<\/li>\n<li>Start the circulating pump and allow it to operate for approximately 2\u20133 minutes.<\/li>\n<li>Confirm that the spray distribution is uniform.<\/li>\n<li>Start the ventilation fan and gradually introduce the exhaust gas.<\/li>\n<li>Check the pressure, liquid circulation, dosing condition and outlet gas quality.<\/li>\n<\/ol>\n<h3>Shutdown Procedure<\/h3>\n<ol>\n<li>Stop the ventilation fan first.<\/li>\n<li>Allow the circulating pump to continue operating for approximately 1\u20132 minutes.<\/li>\n<li>Stop the circulating pump.<\/li>\n<li>Drain, replace or treat the washing liquid when required.<\/li>\n<\/ol>\n<h3>Operation and Maintenance<\/h3>\n<ul>\n<li>Regularly check the pH value and pollutant concentration of the circulating liquid.<\/li>\n<li>Replace or treat the washing liquid when its absorption capacity reaches the specified limit.<\/li>\n<li>Inspect the outlet gas purification performance.<\/li>\n<li>Clean the spray nozzles when the spray pattern becomes uneven.<\/li>\n<li>Inspect the packing for blockage, fouling or deformation.<\/li>\n<li>Check the mist eliminator and clean it when pressure loss increases.<\/li>\n<li>Inspect the circulating pump, valves, piping and seals for leakage.<\/li>\n<li>Check the automatic chemical dosing system and chemical storage level.<\/li>\n<li>Maintain operation, cleaning and liquid-replacement records.<\/li>\n<\/ul>\n<p>A comprehensive inspection is generally recommended after approximately 18\u201324 months of operation, depending on the actual working conditions. The spray piping, packing material, mist eliminator and liquid circulation system should be inspected and cleaned as necessary.<\/p>\n<h3>Selection Considerations<\/h3>\n<ul>\n<li>Required treatment airflow<\/li>\n<li>Pollutant type and concentration<\/li>\n<li>Exhaust gas temperature and humidity<\/li>\n<li>Acidic or alkaline properties<\/li>\n<li>Dust and particulate concentration<\/li>\n<li>Required removal efficiency<\/li>\n<li>Suitable washing liquid and dosing chemicals<\/li>\n<li>Required tower construction material<\/li>\n<li>Available installation height and floor space<\/li>\n<li>Local emission and safety requirements<\/li>\n<\/ul>\n<h3>Why Choose ES Air EXL Series?<\/h3>\n<ul>\n<li>Designed for water-soluble, acidic and alkaline industrial exhaust gas<\/li>\n<li>Combines gas absorption, chemical neutralization and dust collection<\/li>\n<li>Compact vertical structure saves floor space<\/li>\n<li>Multiple corrosion-resistant materials available<\/li>\n<li>Optional automatic dosing and pretreatment configurations<\/li>\n<li>Can be integrated with other exhaust gas treatment systems<\/li>\n<li>Customized engineering according to actual working conditions<\/li>\n<li>Simple operation and convenient maintenance<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is a vertical spray scrubber?<\/h4>\n<p>A vertical spray scrubber is an industrial air-pollution-control device that uses a circulating liquid to absorb water-soluble gases, neutralize acidic or alkaline pollutants and capture particulate matter.<\/p>\n<h4>What pollutants can the EXL series treat?<\/h4>\n<p>The EXL series is suitable for many acidic gases, alkaline gases, water-soluble pollutants, industrial odors and micron-sized particulate matter.<\/p>\n<h4>Why is chemical dosing required?<\/h4>\n<p>Chemical dosing adjusts the washing-liquid chemistry and promotes rapid neutralization of acidic or alkaline pollutants.<\/p>\n<h4>What is the purpose of the packing layer?<\/h4>\n<p>The packing layer increases the gas-liquid contact area and improves mass-transfer and pollutant absorption efficiency.<\/p>\n<h4>What is the purpose of the mist eliminator?<\/h4>\n<p>The mist eliminator removes liquid droplets entrained in the treated gas before discharge.<\/p>\n<h4>When should the washing liquid be replaced?<\/h4>\n<p>The liquid should be replaced or treated when its pollutant concentration, pH or absorption capacity reaches the specified operating limit.<\/p>\n<h4>Can the scrubber be installed outdoors?<\/h4>\n<p>Yes. Outdoor installation is available, but rain protection and anti-freezing measures may be required according to the local climate.<\/p>\n<h4>Can ES Air customize the vertical spray scrubber?<\/h4>\n<p>Yes. ES Air can customize the tower according to airflow, pollutant composition, temperature, corrosion level, treatment efficiency, installation height and project requirements.<\/p>\n<h3>Customized Acid and Alkaline Exhaust Gas Treatment Solutions<\/h3>\n<p>ES Air provides vertical spray scrubbers and integrated industrial exhaust gas treatment systems for chemical, pharmaceutical, electronics, metal processing and other industrial applications.<\/p>\n<p>Contact ES Air for working-condition evaluation, material selection, process design and customized scrubber solutions.<\/p>\n<p style=\"margin-top: 30px;\"><em><br \/>\nSEO Brief: The ES Air EXL Series Vertical Spray Scrubber is designed for water-soluble, acidic and alkaline industrial exhaust gas. It combines spray absorption, packing mass transfer, chemical neutralization and mist elimination to remove gaseous pollutants and particulate matter. Available in PP, FRP, Q235B carbon steel and SUS304 stainless steel, the system is suitable for chemical, pharmaceutical, electronics, metal processing, electroplating and industrial furnace applications.<br \/>\n<\/em><\/p>\n\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p PcOnly sticky\" style=\"font-size:16px;line-height:36px;color:#808080;background-color:#ffffff; border:1px #d7d7d7 solid;padding:30px 30px;border-radius:15px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h1 class=\"wp-block-heading has-black-color has-text-color has-link-color has-large-font-size wp-elements-99555ae3e05f4a5d9cb6e2edfc3ca2f8\">Vertical Spray Scrubber<\/h1>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-c5cc62a0dabaa5abb57a7d937ee66cab wp-block-paragraph\" style=\"font-size:18px\"><strong>Product Classification<\/strong><\/p>\n\n\n\n<a href=\"https:\/\/www.esair-equip.com\/vi\/category\/product\/acid-base-waste-gas-purification-equipment\">Thi\u1ebft b\u1ecb x\u1eed l\u00fd kh\u00ed th\u1ea3i axit-baz\u01a1<\/a> \n\n\n\n<div class=\"wp-block-themepark-block-themepark-xian theme_fang_out\" style=\"text-align:left;padding-top:15px;padding-bottom:15px;\"><div class=\"fangbox\" style=\"width:100%;height:1px;background-color:#e6e6e6;\"><\/div><\/div>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color has-medium-font-size wp-elements-7b3681ca418359f06d4d62aa6a3c41ca wp-block-paragraph\"><strong>Scope of Application<\/strong><\/p>\n\n\n\n<p class=\"has-monte-grey-color has-text-color has-link-color wp-elements-434dba10dab9870bd3f4392b641f9397 wp-block-paragraph\"><\/p>\n\n\n<p>The EXL series vertical spray scrubber is specifically designed for treating most water-soluble pollutants as well as acidic and alkaline exhaust gases.<\/p>\n<p>In addition to removing water-soluble contaminants from industrial exhaust streams, the scrubber can also capture particulate matter larger than the micron level.<\/p>\n<p>Its basic operating principle is to bring the contaminated gas into full contact with the scrubbing liquid, transferring pollutants from the gas phase into the liquid phase. The purified gas is then separated from the contaminated liquid, achieving effective exhaust gas treatment.<\/p>\n\n\n\n\n<p class=\"has-monte-grey-color has-text-color has-link-color wp-elements-434dba10dab9870bd3f4392b641f9397 wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-listbox thempark-block themepark_listbox\" style=\"padding-top:15px;text-align:left;\"><ul class=\"themepark_listbox_list\" style=\"padding-left:0%;padding-right:2%;\"><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-envelope\" style=\"color:#009aab;line-height:28px\"><\/i><span>esairsuzhou@vip.163.com<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>0512-57398857<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>13776305335  \u00d4ng Liu<\/span><\/li><li style=\"color:#000000;font-size:18px;line-height:28px;margin-bottom:9px;padding-left:33px;\"><i class=\"fas fa-phone\" style=\"color:#009aab;line-height:28px\"><\/i><span>17312699967 Miss luo<\/span><\/li><\/ul><div class=\"themepark_listbox_ba\" style=\"opacity:1;\"><\/div><\/section>\n\n\n\n<div class=\"wp-block-themepark-block-btn themepark-i-btn-out maodian\" style=\"text-align:undefined;padding-bottom:14px;\"><div class=\"themepark-i-btn-out_ins\" style=\"\"><div class=\"themepark-i-btn-out_in\"><div class=\"themepark-i-btn  active\" style=\"background-color:#009aab;color:#ffffff;font-size:16px;border:solid 1px #009aab;border-radius:20px;padding:5px 23px;\"><i class=\"ri-chat-2-fill\"><\/i><a href=\"#Inquiry\" rel=\"noopener noreferrer \">Inquiry<\/a><a class=\"hovers ri-chat-2-fill\" data-title=\"Inquiry\" style=\"color:#009aab;background-color:#ffffff;padding:5px 23px;border-radius:20px;\" href=\"#Inquiry\" rel=\"noopener noreferrer\" target=\"_self\"><\/a><\/div><div class=\"themepark-i-btn\" style=\"background-color:#009aab;color:#ffffff;font-size:16px;border:solid 1px #009aab;border-radius:20px;padding:5px 23px;\"><i class=\"ri-apps-fill\"><\/i><a href=\"#Related\" rel=\"noopener noreferrer\" target=\"_self\">Recommendation<\/a><a class=\"hovers ri-apps-fill\" data-title=\"Recommendation\" style=\"color:#009aab;background-color:#ffffff;padding:5px 23px;border-radius:20px;\" href=\"#Related\" rel=\"noopener noreferrer\" target=\"_self\"><\/a><\/div><\/div><\/div><\/div>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-9ac00cf961d1ea846fe5a532228b76c6 wp-block-paragraph\"><\/p>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-listbox thempark-block themepark_listbox iconmodle  undefined\" style=\"padding-top:13px;text-align:left;\"><h3 class=\"themepark_listbox_title\" style=\"color:#666666;font-size:18px;\"><span>Share on social media<\/span><\/h3><ul class=\"themepark_listbox_list\" style=\"\"><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-facebook\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>facebook<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/twitter.com\/intent\/tweet?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026text=\"><i class=\"fab fa-twitter\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/twitter.com\/intent\/tweet?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026text=\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>twitter<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.linkedin.com\/shareArticle?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=\"><i class=\"fab fa-linkedin\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.linkedin.com\/shareArticle?url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>linkedin<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/api.whatsapp.com\/send?text= https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-whatsapp\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/api.whatsapp.com\/send?text= https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>whatsapp<\/span><\/a><\/li><li style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><a href=\"https:\/\/www.linkedin.com\/shareArticle?mini=trueu0026url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=u0026summary=u0026source=https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fab fa-linkedin\" style=\"color:#fff;line-height:26px\"><\/i><\/a><a href=\"https:\/\/www.linkedin.com\/shareArticle?mini=trueu0026url=https:\/\/www.esair-equip.com\/vi\/1022.htmlu0026title=u0026summary=u0026source=https:\/\/www.esair-equip.com\/vi\/1022.html\" style=\"background-color:#e21f2f;color:#fff;font-size:16px;line-height:26px;margin-bottom:8px;\"><span>linkedin<\/span><\/a><\/li><\/ul><div class=\"themepark_listbox_ba\" style=\"opacity:1;\"><\/div><\/section>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-xian theme_fang_out\" style=\"text-align:left;padding-top:15px;padding-bottom:15px;\"><div class=\"fangbox\" style=\"width:100%;height:1px;background-color:#e6e6e6;\"><\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"padding-bottom:42px;padding-top:49px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:16px;line-height:29px;color:#ffffff;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-center has-medium-font-size\" id=\"Inquiry\">Send Inquiry<\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Interested in our products? Fill out the inquiry form below, and our account manager will contact you within 24 hours<\/p>\n\n\n\n<div class=\"wp-block-themepark-block-themepark-comment thempark-block themepark-comment fromnopading undefined\" style=\"padding-bottom:20px;padding-top:20px;max-width:1920px;\"><div class=\"themepark-comment_in\" id=\"ud_form\"><div class=\"themepark-comment_inb2\"><div class=\"themepark-comment_inb\" style=\"\"><div class=\"themepark-comment_form nolable\" style=\"\"><form id=\"commentform-park\" class=\"themepark-c-f\" action=\"https:\/\/www.esair-equip.com\/wp-comments-post.php\" method=\"post\" autocomplete=\"off\" data-trp-original-action=\"https:\/\/www.esair-equip.com\/wp-comments-post.php\"><div class=\"themepark-comment_form_box tptext\" style=\"font-size:14px;\"><lable for=\"tpcommet0\" class=\"\"><input type=\"text\" id=\"tpcommet0\" name=\"tpcommet0\" size=\"28\" style=\"\" placeholder=\"Name\"\/><\/lable><\/div><div class=\"themepark-comment_form_box tptext tel-c\" style=\"font-size:14px;\"><lable for=\"tpcommet1\" class=\"\"><input type=\"text\" class=\"f-tel\" id=\"tpcommet1\" name=\"tpcommet1\" size=\"28\" style=\"\" placeholder=\"\u0110i\u1ec7n tho\u1ea1i\"\/><\/lable><\/div><div class=\"themepark-comment_form_box tptext mail-c\" style=\"font-size:14px;\"><lable for=\"tpcommet2\" class=\"required\"><input type=\"text\" class=\"f-email\" id=\"tpcommet2\" name=\"tpcommet2\" size=\"28\" required style=\"\" placeholder=\"Email\"\/><span class=\"required\">*<div class=\"required_tishi animated\"><i class=\"fas fa-exclamation-circle\"><\/i><span><\/span><\/div><\/span><\/lable><\/div><div class=\"themepark-comment_form_box tpTextarea\" style=\"font-size:14px;\"><lable for=\"tpcommet3\"><textarea id=\"tpcommet3\" name=\"tpcommet3\" style=\"\" placeholder=\"Th\u00f4ng \u0111i\u1ec7p\"><\/textarea><\/lable><\/div><div class=\"hiddeninput\"><input name=\"comment_post_ID\" type=\"hidden\" value=\"151\"\/><input name=\"author\" type=\"hidden\" class=\"author\"\/><input name=\"email\" type=\"hidden\" class=\"email\"\/><textarea name=\"comment\" style=\"display:none\" class=\"comment\"><\/textarea><input name=\"themeparklable\" type=\"hidden\" value=\"Name|Tel|E-mail|Message\"\/><input name=\"themeparktype\" type=\"hidden\" value=\"text|text3|text2|Textarea\"\/><input name=\"redirect_to\" type=\"hidden\" value=\"https:\/\/www.esair-equip.com\"\/><input name=\"inquiryid\" type=\"hidden\"\/><input name=\"inquirytime\" type=\"hidden\"\/><input name=\"position\" type=\"hidden\"\/><\/div><div class=\"submut_box\"><input type=\"submit\" class=\"submut_btn\" name=\"submit\" style=\"background:#009aab;\" value=\"Send inquiry\"\/><div class=\"tishi\" style=\"\"><div class=\"loading\" style=\"\"><i class=\"fas fa-spinner\"><\/i>Submitting!<\/div><div class=\"success\" style=\"\"><i class=\"fas fa-check\"><\/i>Submission successful!<\/div><div class=\"erro\" style=\"\"><i class=\"fas fa-exclamation-circle\"><\/i>Submission failed!<\/div><div class=\"e-email\">E-mail error!<\/div><div class=\"e-tel\">Phone error!<\/div><\/div><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"vi\"\/><\/form><\/div><div class=\"wp_clear\"><\/div><\/div><div class=\"themepark-comment_in_b\" style=\"opacity:1;undefined0\"><\/div><\/div><\/div><div class=\"wp_clear\"><\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"layout_badh\"><div class=\"PcOnly themepark-block_layout_ba lazyload swiper-lazy\" style=\"\" data-background=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/88d1e6dc-3a97-4a53-a143-8abe926b79b5.jpg\"><\/div><div class=\"MovePnly themepark-block_layout_ba lazyload swiper-move-lazy\" style=\"\" data-background=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/05\/88d1e6dc-3a97-4a53-a143-8abe926b79b5.jpg\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"padding-bottom:59px;padding-top:63px;\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-center has-medium-font-size\" id=\"Related\">Recommended products<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"product_loop  zhong  radius   mian_loop\" id=\"pro_list_4\"><div class=\"product_post   h_w\" ><a href=\"https:\/\/www.esair-equip.com\/vi\/937.html\" class=\"product_pic postatty\" ><img loading=\"lazy\" decoding=\"async\" class=\"lazyload\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loadings.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/17599946875130331.jpg\" width=\"568\" height=\"426\" alt=\"Electrostatic Oil Mist Collector (EDY Series)\" title=\"Electrostatic Oil Mist Collector (EDY Series)\"\/><\/a><div class=\"product_info\"><h3 class=\"pro_title\"><a href=\"https:\/\/www.esair-equip.com\/vi\/937.html\">Electrostatic Oil Mist Collector (EDY Series)<\/a><\/h3><a  class=\"probtn\"href=\"https:\/\/www.esair-equip.com\/vi\/937.html\"><i class=\"fas fa-chevron-circle-right\"><\/i>Xem chi ti\u1ebft<\/a><\/div><\/div><div class=\"product_post   h_w\" ><a href=\"https:\/\/www.esair-equip.com\/vi\/895.html\" class=\"product_pic postatty\" ><img loading=\"lazy\" decoding=\"async\" class=\"lazyload\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loadings.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/07\/1765264522368815-1024x767.jpg\" width=\"1024\" height=\"767\" alt=\"Baghouse Dust Collector\" title=\"Baghouse Dust Collector\"\/><\/a><div class=\"product_info\"><h3 class=\"pro_title\"><a href=\"https:\/\/www.esair-equip.com\/vi\/895.html\">Baghouse Dust Collector<\/a><\/h3><a  class=\"probtn\"href=\"https:\/\/www.esair-equip.com\/vi\/895.html\"><i class=\"fas fa-chevron-circle-right\"><\/i>Xem chi ti\u1ebft<\/a><\/div><\/div><div class=\"product_post   h_w\" ><a href=\"https:\/\/www.esair-equip.com\/vi\/1022.html\" class=\"product_pic postatty\" ><img loading=\"lazy\" decoding=\"async\" class=\"lazyload\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loadings.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356-1024x767.jpg\" width=\"1024\" height=\"767\" alt=\"Vertical Spray Scrubber\" title=\"Vertical Spray Scrubber\"\/><\/a><div class=\"product_info\"><h3 class=\"pro_title\"><a href=\"https:\/\/www.esair-equip.com\/vi\/1022.html\">Vertical Spray Scrubber<\/a><\/h3><a  class=\"probtn\"href=\"https:\/\/www.esair-equip.com\/vi\/1022.html\"><i class=\"fas fa-chevron-circle-right\"><\/i>Xem chi ti\u1ebft<\/a><\/div><\/div><div class=\"product_post   h_w\" ><a href=\"https:\/\/www.esair-equip.com\/vi\/978.html\" class=\"product_pic postatty\" ><img loading=\"lazy\" decoding=\"async\" class=\"lazyload\" src=\"https:\/\/www.esair-equip.com\/wp-content\/themes\/smartenterprise\/images\/loadings.png\" data-src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993187487244.jpg\" width=\"640\" height=\"426\" alt=\"Zeolite Rotary Adsorption and Desorption System\" title=\"Zeolite Rotary Adsorption and Desorption System\"\/><\/a><div class=\"product_info\"><h3 class=\"pro_title\"><a href=\"https:\/\/www.esair-equip.com\/vi\/978.html\">Zeolite Rotary Adsorption and Desorption System<\/a><\/h3><a  class=\"probtn\"href=\"https:\/\/www.esair-equip.com\/vi\/978.html\"><i class=\"fas fa-chevron-circle-right\"><\/i>Xem chi ti\u1ebft<\/a><\/div><\/div><\/div><\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":1021,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"100%","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":true,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":true,"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","footnotes":""},"categories":[25],"tags":[],"class_list":["post-1022","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acid-base-waste-gas-purification-equipment"],"metadata":{"themepark_auto_meta_ector0":["<h3>Product Overview<\/h3>\r\nThe EXL series vertical spray scrubber is specially designed for treating most water-soluble pollutants as well as acidic and alkaline industrial exhaust gases.\r\n\r\nIn addition to removing water-soluble gaseous contaminants, the system can also capture micron-sized and larger particulate matter. Its basic treatment principle is to bring the contaminated gas into full contact with a scrubbing liquid, transfer pollutants from the gas phase into the liquid phase, and then separate the purified gas from the contaminated liquid.\r\n\r\nUnder controlled temperature and pressure conditions, the circulating spray system delivers the washing liquid through high-pressure nozzles. High-efficiency packing material increases the gas-liquid contact area and helps atomize the liquid into fine droplets.\r\n\r\nAt the beginning of gas-liquid contact, pollutant dissolution and absorption are the dominant processes. As the concentration of absorbed pollutants in the washing liquid increases, the absorption rate gradually decreases while the desorption rate increases.\r\n\r\nWhen the absorption and desorption rates become equal, the system reaches gas-liquid phase equilibrium and the net absorption process stops. At this stage, the saturated washing liquid should be replaced or treated. Otherwise, the absorbed pollutants may escape from the liquid phase and return to the gas phase.\r\n\r\nFor acid or alkaline exhaust gas treatment, the scrubber can be equipped with an automatic chemical dosing system. Sulfuric acid, alkaline solution or another suitable reagent is introduced into the circulating liquid to react rapidly with the target pollutants and improve neutralization efficiency.\r\n\r\n<!-- Image 2: Working Principle or Internal Structure Diagram -->\r\n\r\n<img class=\"aligncenter wp-image-1028 size-full\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5.png\" alt=\"Vertical Spray Scrubber Working Principle\" width=\"1286\" height=\"1223\" \/>\r\n<h3>Working Principle<\/h3>\r\nThe EXL vertical spray scrubber mainly consists of the tower body, spray sections, packing layers, mist elimination section, circulating-water piping, circulation tank and circulating pump.\r\n\r\nThe spray sections generally use spiral nozzles and high-efficiency packing materials such as Pall rings. Transparent inspection windows can be installed to allow convenient observation of the internal spray and packing conditions.\r\n\r\nThe mist elimination section can use swirl plates, Raschig rings or other demisting media to remove entrained water droplets from the treated gas.\r\n\r\nThe circulating pump can be selected from corrosion-resistant plastic pumps or stainless steel centrifugal pumps according to the washing-liquid composition and operating conditions.\r\n\r\nOther components, including plastic piping, valves, support frames, inspection ladders and inlet ducts, can be customized according to project requirements.\r\n\r\nThe vertical spray scrubber is a counter-current gas-liquid absorption tower. Contaminated gas enters tangentially through the lower inlet and rapidly fills the inlet section under the action of the ventilation fan.\r\n\r\nThe gas then rises evenly through the flow-distribution section. In the spray zone, the absorption liquid is atomized through evenly arranged nozzles, forming fine droplets that fully mix and contact the rising gas.\r\n\r\nDuring this contact process, soluble pollutants transfer into the liquid phase, while acidic or alkaline components react with the corresponding chemical solution.\r\n\r\nThe treated gas then passes through the mist eliminator to remove entrained droplets. Purified gas exits through the top outlet and is discharged through the exhaust stack after meeting the applicable emission requirements.\r\n<h3>Treatment Process<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Process Stage<\/strong><\/td>\r\n<td><strong>Description<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>1. Exhaust Gas Collection<\/strong><\/td>\r\n<td>Contaminated gas is collected through extraction hoods and transported to the scrubber through the duct system.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>2. Gas Distribution<\/strong><\/td>\r\n<td>The inlet and distribution section guide the gas evenly into the absorption zone.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>3. Spray Absorption<\/strong><\/td>\r\n<td>The circulating liquid is atomized through high-pressure nozzles and fully contacts the rising gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>4. Packing Mass Transfer<\/strong><\/td>\r\n<td>High-efficiency packing increases the contact area between the gas and liquid phases.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>5. Chemical Neutralization<\/strong><\/td>\r\n<td>Acidic or alkaline pollutants react with the automatically dosed washing solution.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>6. Mist Elimination<\/strong><\/td>\r\n<td>The mist eliminator removes liquid droplets entrained in the purified gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>7. Purified Gas Discharge<\/strong><\/td>\r\n<td>The treated gas exits through the upper outlet and is discharged through the exhaust stack.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>8. Liquid Circulation<\/strong><\/td>\r\n<td>The washing liquid returns to the circulation tank for reuse until replacement or treatment is required.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Main Components<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Component<\/strong><\/td>\r\n<td><strong>Function<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Vertical Tower Body<\/td>\r\n<td>Provides the enclosed space required for gas distribution, spraying, absorption and mist removal.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Spray Section<\/td>\r\n<td>Uses nozzles to atomize the washing liquid and maximize gas-liquid contact.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Packing Layer<\/td>\r\n<td>Increases the effective mass-transfer area and improves pollutant absorption efficiency.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Mist Eliminator<\/td>\r\n<td>Removes water droplets entrained in the treated gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Circulation Tank<\/td>\r\n<td>Stores the washing liquid for continuous recirculation.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Circulating Pump<\/td>\r\n<td>Delivers the washing liquid from the tank to the spray nozzles.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Automatic Dosing System<\/td>\r\n<td>Adds acid, alkali or other treatment chemicals according to the pollutant characteristics.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Inspection Window<\/td>\r\n<td>Allows observation of the internal spray and packing conditions.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Maintenance Door<\/td>\r\n<td>Provides access for cleaning, inspection and packing replacement.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Piping and Valves<\/td>\r\n<td>Control liquid circulation, drainage, replenishment and chemical dosing.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Key Features<\/h3>\r\n<ul>\r\n \t<li>Efficient absorption and neutralization of toxic and harmful gases<\/li>\r\n \t<li>Dust collection efficiency can generally exceed 90% under suitable operating conditions<\/li>\r\n \t<li>Suitable for water-soluble, acidic and alkaline pollutants<\/li>\r\n \t<li>Stable and reliable performance<\/li>\r\n \t<li>Simple operation and convenient maintenance<\/li>\r\n \t<li>Can be used independently or as a pretreatment unit<\/li>\r\n \t<li>Optional packing and automatic chemical dosing systems<\/li>\r\n \t<li>Available treatment airflow from approximately 500 to 100,000 m\u00b3\/h<\/li>\r\n \t<li>Long equipment service life and relatively low maintenance requirements<\/li>\r\n \t<li>Flexible tower materials available according to corrosion and temperature conditions<\/li>\r\n \t<li>Customized tower dimensions and process configurations available<\/li>\r\n<\/ul>\r\n<h3>Available Construction Materials<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Material<\/strong><\/td>\r\n<td><strong>Typical Application<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td>PP<\/td>\r\n<td>Suitable for many acidic, alkaline and corrosive exhaust gas treatment applications.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>FRP<\/td>\r\n<td>Provides good corrosion resistance and structural strength for industrial scrubber systems.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Q235B Carbon Steel<\/td>\r\n<td>Suitable for less corrosive conditions with appropriate coating or internal lining.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>SUS304 Stainless Steel<\/td>\r\n<td>Suitable for applications requiring improved corrosion resistance, mechanical strength and cleanliness.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Applicable Pollutants<\/h3>\r\n<ul>\r\n \t<li>Acidic exhaust gas<\/li>\r\n \t<li>Alkaline exhaust gas<\/li>\r\n \t<li>Water-soluble organic and inorganic pollutants<\/li>\r\n \t<li>Acid mist<\/li>\r\n \t<li>Ammonia and alkaline vapors<\/li>\r\n \t<li>Sulfur-containing gases<\/li>\r\n \t<li>Industrial odors<\/li>\r\n \t<li>Fine dust and particulate matter<\/li>\r\n \t<li>High-temperature dusty gas after suitable cooling treatment<\/li>\r\n<\/ul>\r\n<h3>Applicable Industries<\/h3>\r\n<ul>\r\n \t<li>Chemical manufacturing<\/li>\r\n \t<li>Food processing<\/li>\r\n \t<li>Pharmaceutical production<\/li>\r\n \t<li>Electronics manufacturing<\/li>\r\n \t<li>Steel and metallurgical industries<\/li>\r\n \t<li>Non-ferrous metal processing<\/li>\r\n \t<li>Mining and mineral processing<\/li>\r\n \t<li>Industrial furnace exhaust treatment<\/li>\r\n \t<li>Pickling and metal surface treatment<\/li>\r\n \t<li>Electroplating production<\/li>\r\n \t<li>Battery manufacturing<\/li>\r\n \t<li>Laboratory exhaust systems<\/li>\r\n \t<li>Other industries generating soluble or corrosive exhaust gases<\/li>\r\n<\/ul>\r\n<!-- Image 3: Application Site or Installation Image -->\r\n\r\n<img class=\"wp-image-1027 size-full aligncenter\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993719847768.png\" alt=\"Industrial Application of Vertical Spray Scrubber\" width=\"293\" height=\"576\" \/>\r\n<h3>Installation Instructions<\/h3>\r\n<ol>\r\n \t<li>Install the vertical spray scrubber on a reinforced concrete foundation at least 150 mm above ground level. Separate concrete foundations should be prepared for the pump and fan where required.<\/li>\r\n \t<li>Protect the equipment body, nozzles, packing, piping and other components from impact or damage during transportation and installation.<\/li>\r\n \t<li>Depending on the equipment dimensions and transportation conditions, the scrubber may be delivered in sections and assembled on site.<\/li>\r\n \t<li>For outdoor installation in cold climates, provide anti-freezing protection for the bottom circulation tank, water piping and pump during winter.<\/li>\r\n \t<li>Fill the circulation tank with the required absorption liquid to the marked operating level before startup. Replenish the liquid during operation when necessary.<\/li>\r\n \t<li>Reserve adequate space around the scrubber for inspection, cleaning, packing replacement and pump servicing.<\/li>\r\n \t<li>Confirm that the fan, pump, valves, dosing system and electrical controls operate correctly before introducing contaminated gas.<\/li>\r\n<\/ol>\r\n<h3>Startup Procedure<\/h3>\r\n<ol>\r\n \t<li>Check the liquid level in the circulation tank.<\/li>\r\n \t<li>Confirm that the spray nozzles, valves and piping are unobstructed.<\/li>\r\n \t<li>Start the circulating pump and allow it to operate for approximately 2\u20133 minutes.<\/li>\r\n \t<li>Confirm that the spray distribution is uniform.<\/li>\r\n \t<li>Start the ventilation fan and gradually introduce the exhaust gas.<\/li>\r\n \t<li>Check the pressure, liquid circulation, dosing condition and outlet gas quality.<\/li>\r\n<\/ol>\r\n<h3>Shutdown Procedure<\/h3>\r\n<ol>\r\n \t<li>Stop the ventilation fan first.<\/li>\r\n \t<li>Allow the circulating pump to continue operating for approximately 1\u20132 minutes.<\/li>\r\n \t<li>Stop the circulating pump.<\/li>\r\n \t<li>Drain, replace or treat the washing liquid when required.<\/li>\r\n<\/ol>\r\n<h3>Operation and Maintenance<\/h3>\r\n<ul>\r\n \t<li>Regularly check the pH value and pollutant concentration of the circulating liquid.<\/li>\r\n \t<li>Replace or treat the washing liquid when its absorption capacity reaches the specified limit.<\/li>\r\n \t<li>Inspect the outlet gas purification performance.<\/li>\r\n \t<li>Clean the spray nozzles when the spray pattern becomes uneven.<\/li>\r\n \t<li>Inspect the packing for blockage, fouling or deformation.<\/li>\r\n \t<li>Check the mist eliminator and clean it when pressure loss increases.<\/li>\r\n \t<li>Inspect the circulating pump, valves, piping and seals for leakage.<\/li>\r\n \t<li>Check the automatic chemical dosing system and chemical storage level.<\/li>\r\n \t<li>Maintain operation, cleaning and liquid-replacement records.<\/li>\r\n<\/ul>\r\nA comprehensive inspection is generally recommended after approximately 18\u201324 months of operation, depending on the actual working conditions. The spray piping, packing material, mist eliminator and liquid circulation system should be inspected and cleaned as necessary.\r\n<h3>Selection Considerations<\/h3>\r\n<ul>\r\n \t<li>Required treatment airflow<\/li>\r\n \t<li>Pollutant type and concentration<\/li>\r\n \t<li>Exhaust gas temperature and humidity<\/li>\r\n \t<li>Acidic or alkaline properties<\/li>\r\n \t<li>Dust and particulate concentration<\/li>\r\n \t<li>Required removal efficiency<\/li>\r\n \t<li>Suitable washing liquid and dosing chemicals<\/li>\r\n \t<li>Required tower construction material<\/li>\r\n \t<li>Available installation height and floor space<\/li>\r\n \t<li>Local emission and safety requirements<\/li>\r\n<\/ul>\r\n<h3>Why Choose ES Air EXL Series?<\/h3>\r\n<ul>\r\n \t<li>Designed for water-soluble, acidic and alkaline industrial exhaust gas<\/li>\r\n \t<li>Combines gas absorption, chemical neutralization and dust collection<\/li>\r\n \t<li>Compact vertical structure saves floor space<\/li>\r\n \t<li>Multiple corrosion-resistant materials available<\/li>\r\n \t<li>Optional automatic dosing and pretreatment configurations<\/li>\r\n \t<li>Can be integrated with other exhaust gas treatment systems<\/li>\r\n \t<li>Customized engineering according to actual working conditions<\/li>\r\n \t<li>Simple operation and convenient maintenance<\/li>\r\n<\/ul>\r\n<h3>Frequently Asked Questions<\/h3>\r\n<h4>What is a vertical spray scrubber?<\/h4>\r\nA vertical spray scrubber is an industrial air-pollution-control device that uses a circulating liquid to absorb water-soluble gases, neutralize acidic or alkaline pollutants and capture particulate matter.\r\n<h4>What pollutants can the EXL series treat?<\/h4>\r\nThe EXL series is suitable for many acidic gases, alkaline gases, water-soluble pollutants, industrial odors and micron-sized particulate matter.\r\n<h4>Why is chemical dosing required?<\/h4>\r\nChemical dosing adjusts the washing-liquid chemistry and promotes rapid neutralization of acidic or alkaline pollutants.\r\n<h4>What is the purpose of the packing layer?<\/h4>\r\nThe packing layer increases the gas-liquid contact area and improves mass-transfer and pollutant absorption efficiency.\r\n<h4>What is the purpose of the mist eliminator?<\/h4>\r\nThe mist eliminator removes liquid droplets entrained in the treated gas before discharge.\r\n<h4>When should the washing liquid be replaced?<\/h4>\r\nThe liquid should be replaced or treated when its pollutant concentration, pH or absorption capacity reaches the specified operating limit.\r\n<h4>Can the scrubber be installed outdoors?<\/h4>\r\nYes. Outdoor installation is available, but rain protection and anti-freezing measures may be required according to the local climate.\r\n<h4>Can ES Air customize the vertical spray scrubber?<\/h4>\r\nYes. ES Air can customize the tower according to airflow, pollutant composition, temperature, corrosion level, treatment efficiency, installation height and project requirements.\r\n<h3>Customized Acid and Alkaline Exhaust Gas Treatment Solutions<\/h3>\r\nES Air provides vertical spray scrubbers and integrated industrial exhaust gas treatment systems for chemical, pharmaceutical, electronics, metal processing and other industrial applications.\r\n\r\nContact ES Air for working-condition evaluation, material selection, process design and customized scrubber solutions.\r\n<p style=\"margin-top: 30px;\"><em>\r\nSEO Brief: The ES Air EXL Series Vertical Spray Scrubber is designed for water-soluble, acidic and alkaline industrial exhaust gas. It combines spray absorption, packing mass transfer, chemical neutralization and mist elimination to remove gaseous pollutants and particulate matter. Available in PP, FRP, Q235B carbon steel and SUS304 stainless steel, the system is suitable for chemical, pharmaceutical, electronics, metal processing, electroplating and industrial furnace applications.\r\n<\/em><\/p>"],"themepark_auto_meta_ector1":["The EXL series vertical spray scrubber is specifically designed for treating most water-soluble pollutants as well as acidic and alkaline exhaust gases.\r\n\r\nIn addition to removing water-soluble contaminants from industrial exhaust streams, the scrubber can also capture particulate matter larger than the micron level.\r\n\r\nIts basic operating principle is to bring the contaminated gas into full contact with the scrubbing liquid, transferring pollutants from the gas phase into the liquid phase. The purified gas is then separated from the contaminated liquid, achieving effective exhaust gas treatment."],"themepark_auto_meta_slideb2":["1021,1023,1024,1025"],"themepark_post_bcolor":["#f5f5f5"],"themepark_post_width":["100%"],"themepark_post_img_po":["left"],"themepark_post_hide_title":["1"],"themepark_post_main_p":["100"],"themepark_paddingblock":["1"],"themepark_auto_metas":["a:3:{s:6:\"ector0\";s:16321:\"<h3>Product Overview<\/h3>\r\nThe EXL series vertical spray scrubber is specially designed for treating most water-soluble pollutants as well as acidic and alkaline industrial exhaust gases.\r\n\r\nIn addition to removing water-soluble gaseous contaminants, the system can also capture micron-sized and larger particulate matter. Its basic treatment principle is to bring the contaminated gas into full contact with a scrubbing liquid, transfer pollutants from the gas phase into the liquid phase, and then separate the purified gas from the contaminated liquid.\r\n\r\nUnder controlled temperature and pressure conditions, the circulating spray system delivers the washing liquid through high-pressure nozzles. High-efficiency packing material increases the gas-liquid contact area and helps atomize the liquid into fine droplets.\r\n\r\nAt the beginning of gas-liquid contact, pollutant dissolution and absorption are the dominant processes. As the concentration of absorbed pollutants in the washing liquid increases, the absorption rate gradually decreases while the desorption rate increases.\r\n\r\nWhen the absorption and desorption rates become equal, the system reaches gas-liquid phase equilibrium and the net absorption process stops. At this stage, the saturated washing liquid should be replaced or treated. Otherwise, the absorbed pollutants may escape from the liquid phase and return to the gas phase.\r\n\r\nFor acid or alkaline exhaust gas treatment, the scrubber can be equipped with an automatic chemical dosing system. Sulfuric acid, alkaline solution or another suitable reagent is introduced into the circulating liquid to react rapidly with the target pollutants and improve neutralization efficiency.\r\n\r\n<!-- Image 2: Working Principle or Internal Structure Diagram -->\r\n\r\n<img class=\"aligncenter wp-image-1028 size-full\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/919767df-d77f-4ea4-aa4a-37034da84bf5.png\" alt=\"Vertical Spray Scrubber Working Principle\" width=\"1286\" height=\"1223\" \/>\r\n<h3>Working Principle<\/h3>\r\nThe EXL vertical spray scrubber mainly consists of the tower body, spray sections, packing layers, mist elimination section, circulating-water piping, circulation tank and circulating pump.\r\n\r\nThe spray sections generally use spiral nozzles and high-efficiency packing materials such as Pall rings. Transparent inspection windows can be installed to allow convenient observation of the internal spray and packing conditions.\r\n\r\nThe mist elimination section can use swirl plates, Raschig rings or other demisting media to remove entrained water droplets from the treated gas.\r\n\r\nThe circulating pump can be selected from corrosion-resistant plastic pumps or stainless steel centrifugal pumps according to the washing-liquid composition and operating conditions.\r\n\r\nOther components, including plastic piping, valves, support frames, inspection ladders and inlet ducts, can be customized according to project requirements.\r\n\r\nThe vertical spray scrubber is a counter-current gas-liquid absorption tower. Contaminated gas enters tangentially through the lower inlet and rapidly fills the inlet section under the action of the ventilation fan.\r\n\r\nThe gas then rises evenly through the flow-distribution section. In the spray zone, the absorption liquid is atomized through evenly arranged nozzles, forming fine droplets that fully mix and contact the rising gas.\r\n\r\nDuring this contact process, soluble pollutants transfer into the liquid phase, while acidic or alkaline components react with the corresponding chemical solution.\r\n\r\nThe treated gas then passes through the mist eliminator to remove entrained droplets. Purified gas exits through the top outlet and is discharged through the exhaust stack after meeting the applicable emission requirements.\r\n<h3>Treatment Process<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Process Stage<\/strong><\/td>\r\n<td><strong>Description<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>1. Exhaust Gas Collection<\/strong><\/td>\r\n<td>Contaminated gas is collected through extraction hoods and transported to the scrubber through the duct system.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>2. Gas Distribution<\/strong><\/td>\r\n<td>The inlet and distribution section guide the gas evenly into the absorption zone.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>3. Spray Absorption<\/strong><\/td>\r\n<td>The circulating liquid is atomized through high-pressure nozzles and fully contacts the rising gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>4. Packing Mass Transfer<\/strong><\/td>\r\n<td>High-efficiency packing increases the contact area between the gas and liquid phases.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>5. Chemical Neutralization<\/strong><\/td>\r\n<td>Acidic or alkaline pollutants react with the automatically dosed washing solution.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>6. Mist Elimination<\/strong><\/td>\r\n<td>The mist eliminator removes liquid droplets entrained in the purified gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>7. Purified Gas Discharge<\/strong><\/td>\r\n<td>The treated gas exits through the upper outlet and is discharged through the exhaust stack.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>8. Liquid Circulation<\/strong><\/td>\r\n<td>The washing liquid returns to the circulation tank for reuse until replacement or treatment is required.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Main Components<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Component<\/strong><\/td>\r\n<td><strong>Function<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Vertical Tower Body<\/td>\r\n<td>Provides the enclosed space required for gas distribution, spraying, absorption and mist removal.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Spray Section<\/td>\r\n<td>Uses nozzles to atomize the washing liquid and maximize gas-liquid contact.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Packing Layer<\/td>\r\n<td>Increases the effective mass-transfer area and improves pollutant absorption efficiency.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Mist Eliminator<\/td>\r\n<td>Removes water droplets entrained in the treated gas.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Circulation Tank<\/td>\r\n<td>Stores the washing liquid for continuous recirculation.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Circulating Pump<\/td>\r\n<td>Delivers the washing liquid from the tank to the spray nozzles.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Automatic Dosing System<\/td>\r\n<td>Adds acid, alkali or other treatment chemicals according to the pollutant characteristics.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Inspection Window<\/td>\r\n<td>Allows observation of the internal spray and packing conditions.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Maintenance Door<\/td>\r\n<td>Provides access for cleaning, inspection and packing replacement.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Piping and Valves<\/td>\r\n<td>Control liquid circulation, drainage, replenishment and chemical dosing.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Key Features<\/h3>\r\n<ul>\r\n \t<li>Efficient absorption and neutralization of toxic and harmful gases<\/li>\r\n \t<li>Dust collection efficiency can generally exceed 90% under suitable operating conditions<\/li>\r\n \t<li>Suitable for water-soluble, acidic and alkaline pollutants<\/li>\r\n \t<li>Stable and reliable performance<\/li>\r\n \t<li>Simple operation and convenient maintenance<\/li>\r\n \t<li>Can be used independently or as a pretreatment unit<\/li>\r\n \t<li>Optional packing and automatic chemical dosing systems<\/li>\r\n \t<li>Available treatment airflow from approximately 500 to 100,000 m\u00b3\/h<\/li>\r\n \t<li>Long equipment service life and relatively low maintenance requirements<\/li>\r\n \t<li>Flexible tower materials available according to corrosion and temperature conditions<\/li>\r\n \t<li>Customized tower dimensions and process configurations available<\/li>\r\n<\/ul>\r\n<h3>Available Construction Materials<\/h3>\r\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"10\">\r\n<tbody>\r\n<tr>\r\n<td><strong>Material<\/strong><\/td>\r\n<td><strong>Typical Application<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td>PP<\/td>\r\n<td>Suitable for many acidic, alkaline and corrosive exhaust gas treatment applications.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>FRP<\/td>\r\n<td>Provides good corrosion resistance and structural strength for industrial scrubber systems.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Q235B Carbon Steel<\/td>\r\n<td>Suitable for less corrosive conditions with appropriate coating or internal lining.<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>SUS304 Stainless Steel<\/td>\r\n<td>Suitable for applications requiring improved corrosion resistance, mechanical strength and cleanliness.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3>Applicable Pollutants<\/h3>\r\n<ul>\r\n \t<li>Acidic exhaust gas<\/li>\r\n \t<li>Alkaline exhaust gas<\/li>\r\n \t<li>Water-soluble organic and inorganic pollutants<\/li>\r\n \t<li>Acid mist<\/li>\r\n \t<li>Ammonia and alkaline vapors<\/li>\r\n \t<li>Sulfur-containing gases<\/li>\r\n \t<li>Industrial odors<\/li>\r\n \t<li>Fine dust and particulate matter<\/li>\r\n \t<li>High-temperature dusty gas after suitable cooling treatment<\/li>\r\n<\/ul>\r\n<h3>Applicable Industries<\/h3>\r\n<ul>\r\n \t<li>Chemical manufacturing<\/li>\r\n \t<li>Food processing<\/li>\r\n \t<li>Pharmaceutical production<\/li>\r\n \t<li>Electronics manufacturing<\/li>\r\n \t<li>Steel and metallurgical industries<\/li>\r\n \t<li>Non-ferrous metal processing<\/li>\r\n \t<li>Mining and mineral processing<\/li>\r\n \t<li>Industrial furnace exhaust treatment<\/li>\r\n \t<li>Pickling and metal surface treatment<\/li>\r\n \t<li>Electroplating production<\/li>\r\n \t<li>Battery manufacturing<\/li>\r\n \t<li>Laboratory exhaust systems<\/li>\r\n \t<li>Other industries generating soluble or corrosive exhaust gases<\/li>\r\n<\/ul>\r\n<!-- Image 3: Application Site or Installation Image -->\r\n\r\n<img class=\"wp-image-1027 size-full aligncenter\" src=\"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1759993719847768.png\" alt=\"Industrial Application of Vertical Spray Scrubber\" width=\"293\" height=\"576\" \/>\r\n<h3>Installation Instructions<\/h3>\r\n<ol>\r\n \t<li>Install the vertical spray scrubber on a reinforced concrete foundation at least 150 mm above ground level. Separate concrete foundations should be prepared for the pump and fan where required.<\/li>\r\n \t<li>Protect the equipment body, nozzles, packing, piping and other components from impact or damage during transportation and installation.<\/li>\r\n \t<li>Depending on the equipment dimensions and transportation conditions, the scrubber may be delivered in sections and assembled on site.<\/li>\r\n \t<li>For outdoor installation in cold climates, provide anti-freezing protection for the bottom circulation tank, water piping and pump during winter.<\/li>\r\n \t<li>Fill the circulation tank with the required absorption liquid to the marked operating level before startup. Replenish the liquid during operation when necessary.<\/li>\r\n \t<li>Reserve adequate space around the scrubber for inspection, cleaning, packing replacement and pump servicing.<\/li>\r\n \t<li>Confirm that the fan, pump, valves, dosing system and electrical controls operate correctly before introducing contaminated gas.<\/li>\r\n<\/ol>\r\n<h3>Startup Procedure<\/h3>\r\n<ol>\r\n \t<li>Check the liquid level in the circulation tank.<\/li>\r\n \t<li>Confirm that the spray nozzles, valves and piping are unobstructed.<\/li>\r\n \t<li>Start the circulating pump and allow it to operate for approximately 2\u20133 minutes.<\/li>\r\n \t<li>Confirm that the spray distribution is uniform.<\/li>\r\n \t<li>Start the ventilation fan and gradually introduce the exhaust gas.<\/li>\r\n \t<li>Check the pressure, liquid circulation, dosing condition and outlet gas quality.<\/li>\r\n<\/ol>\r\n<h3>Shutdown Procedure<\/h3>\r\n<ol>\r\n \t<li>Stop the ventilation fan first.<\/li>\r\n \t<li>Allow the circulating pump to continue operating for approximately 1\u20132 minutes.<\/li>\r\n \t<li>Stop the circulating pump.<\/li>\r\n \t<li>Drain, replace or treat the washing liquid when required.<\/li>\r\n<\/ol>\r\n<h3>Operation and Maintenance<\/h3>\r\n<ul>\r\n \t<li>Regularly check the pH value and pollutant concentration of the circulating liquid.<\/li>\r\n \t<li>Replace or treat the washing liquid when its absorption capacity reaches the specified limit.<\/li>\r\n \t<li>Inspect the outlet gas purification performance.<\/li>\r\n \t<li>Clean the spray nozzles when the spray pattern becomes uneven.<\/li>\r\n \t<li>Inspect the packing for blockage, fouling or deformation.<\/li>\r\n \t<li>Check the mist eliminator and clean it when pressure loss increases.<\/li>\r\n \t<li>Inspect the circulating pump, valves, piping and seals for leakage.<\/li>\r\n \t<li>Check the automatic chemical dosing system and chemical storage level.<\/li>\r\n \t<li>Maintain operation, cleaning and liquid-replacement records.<\/li>\r\n<\/ul>\r\nA comprehensive inspection is generally recommended after approximately 18\u201324 months of operation, depending on the actual working conditions. The spray piping, packing material, mist eliminator and liquid circulation system should be inspected and cleaned as necessary.\r\n<h3>Selection Considerations<\/h3>\r\n<ul>\r\n \t<li>Required treatment airflow<\/li>\r\n \t<li>Pollutant type and concentration<\/li>\r\n \t<li>Exhaust gas temperature and humidity<\/li>\r\n \t<li>Acidic or alkaline properties<\/li>\r\n \t<li>Dust and particulate concentration<\/li>\r\n \t<li>Required removal efficiency<\/li>\r\n \t<li>Suitable washing liquid and dosing chemicals<\/li>\r\n \t<li>Required tower construction material<\/li>\r\n \t<li>Available installation height and floor space<\/li>\r\n \t<li>Local emission and safety requirements<\/li>\r\n<\/ul>\r\n<h3>Why Choose ES Air EXL Series?<\/h3>\r\n<ul>\r\n \t<li>Designed for water-soluble, acidic and alkaline industrial exhaust gas<\/li>\r\n \t<li>Combines gas absorption, chemical neutralization and dust collection<\/li>\r\n \t<li>Compact vertical structure saves floor space<\/li>\r\n \t<li>Multiple corrosion-resistant materials available<\/li>\r\n \t<li>Optional automatic dosing and pretreatment configurations<\/li>\r\n \t<li>Can be integrated with other exhaust gas treatment systems<\/li>\r\n \t<li>Customized engineering according to actual working conditions<\/li>\r\n \t<li>Simple operation and convenient maintenance<\/li>\r\n<\/ul>\r\n<h3>Frequently Asked Questions<\/h3>\r\n<h4>What is a vertical spray scrubber?<\/h4>\r\nA vertical spray scrubber is an industrial air-pollution-control device that uses a circulating liquid to absorb water-soluble gases, neutralize acidic or alkaline pollutants and capture particulate matter.\r\n<h4>What pollutants can the EXL series treat?<\/h4>\r\nThe EXL series is suitable for many acidic gases, alkaline gases, water-soluble pollutants, industrial odors and micron-sized particulate matter.\r\n<h4>Why is chemical dosing required?<\/h4>\r\nChemical dosing adjusts the washing-liquid chemistry and promotes rapid neutralization of acidic or alkaline pollutants.\r\n<h4>What is the purpose of the packing layer?<\/h4>\r\nThe packing layer increases the gas-liquid contact area and improves mass-transfer and pollutant absorption efficiency.\r\n<h4>What is the purpose of the mist eliminator?<\/h4>\r\nThe mist eliminator removes liquid droplets entrained in the treated gas before discharge.\r\n<h4>When should the washing liquid be replaced?<\/h4>\r\nThe liquid should be replaced or treated when its pollutant concentration, pH or absorption capacity reaches the specified operating limit.\r\n<h4>Can the scrubber be installed outdoors?<\/h4>\r\nYes. Outdoor installation is available, but rain protection and anti-freezing measures may be required according to the local climate.\r\n<h4>Can ES Air customize the vertical spray scrubber?<\/h4>\r\nYes. ES Air can customize the tower according to airflow, pollutant composition, temperature, corrosion level, treatment efficiency, installation height and project requirements.\r\n<h3>Customized Acid and Alkaline Exhaust Gas Treatment Solutions<\/h3>\r\nES Air provides vertical spray scrubbers and integrated industrial exhaust gas treatment systems for chemical, pharmaceutical, electronics, metal processing and other industrial applications.\r\n\r\nContact ES Air for working-condition evaluation, material selection, process design and customized scrubber solutions.\r\n<p style=\"margin-top: 30px;\"><em>\r\nSEO Brief: The ES Air EXL Series Vertical Spray Scrubber is designed for water-soluble, acidic and alkaline industrial exhaust gas. It combines spray absorption, packing mass transfer, chemical neutralization and mist elimination to remove gaseous pollutants and particulate matter. Available in PP, FRP, Q235B carbon steel and SUS304 stainless steel, the system is suitable for chemical, pharmaceutical, electronics, metal processing, electroplating and industrial furnace applications.\r\n<\/em><\/p>\";s:6:\"ector1\";s:603:\"The EXL series vertical spray scrubber is specifically designed for treating most water-soluble pollutants as well as acidic and alkaline exhaust gases.\r\n\r\nIn addition to removing water-soluble contaminants from industrial exhaust streams, the scrubber can also capture particulate matter larger than the micron level.\r\n\r\nIts basic operating principle is to bring the contaminated gas into full contact with the scrubbing liquid, transferring pollutants from the gas phase into the liquid phase. The purified gas is then separated from the contaminated liquid, achieving effective exhaust gas treatment.\";s:7:\"slideb2\";s:19:\"1021,1023,1024,1025\";}"],"_thumbnail_id":["1021"],"_autoid":["1"],"_blocktemname":["\u4ea7\u54c1\u8be6\u60c5\u6a21\u677f"]},"medium_url":"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356-300x225.jpg","thumbnail_url":"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356-150x150.jpg","full_url":"https:\/\/www.esair-equip.com\/wp-content\/uploads\/2026\/08\/1765266093341356.jpg","_links":{"self":[{"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/posts\/1022","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/comments?post=1022"}],"version-history":[{"count":1,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/posts\/1022\/revisions"}],"predecessor-version":[{"id":1026,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/posts\/1022\/revisions\/1026"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/media\/1021"}],"wp:attachment":[{"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/media?parent=1022"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/categories?post=1022"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.esair-equip.com\/vi\/wp-json\/wp\/v2\/tags?post=1022"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}